DST1062B 2channels ; 60MHz; 1GSa/s

7-inch colored display, and delivers high bandwidth and sample rate under matchless  price point worldwide; Advanced Functionalities include automatic measurements,  advanced triggering modes, record length. Bring extraordinary user-friendliness  and measurement precision for debug, design, education,  quality control,  training, manufacturing test for a variety of industrial users.

 

Bandwidth:      60 MHz

Real-time Sample Rate:     1GSa/s

Equivalent Sample Rate:    25GSa/s

Record Length(Sample Points) :  Single-channel: Maximum 1M; Dual-channel:Maximum 512K (4K,16K,40K optional)

SEC/DIV Range:           4nS/div-40S/div (in a 2, 4, 8 sequence)

Delay Time Accuracy:     500ps
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
u Vertical


A/D Converter:     8-bit resolution, each channel sampled simultaneously
VOLTS/DIV Range:   2mV/div~5V/div at input BNC
Position Range:    ±50V(5V/div),±40V(2V/div~500mV/div),2V(200mV/div~50mV/div)±400mV(20mV/div~2mV/div)
Bandwidth Limit:   20MHz
Rise Time at BNC:  ≤ 5.8ns
DC Gain Accuracy:  ±4% for Sample or Average acquisition mode, 5mV/div to 2mV/div

                    ±3% for Sample or Average acquisition mode, 5V/div to 10mV/div
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
u Trigger


"Trigger Sensitivity(Edge Trigger Type)" :
DC:     CH1/CH2(Typical)   1div from DC to 

                                                          10MHz;1.5div from 10MHz to Full
                                                EXT(Typical)     200mV from DC to 40MHz
                                                EXT/5(Typical)   1V from DC to 40MHz
                                                AC:     Attenuates signals below 10Hz
                                                HF Reject:      Attenuates signals above 80kHz
                                                LF Reject:      Attenuates signals below 150kHz
                                                Noise Reject:   Reduces trigger sensitivity

Trigger Level Range:   CH1,CH2:  ±8 divisions from center of screen
                                      EXT:±1.2V      EXT/5: ±6V
"Trigger Level Accuracy,typical (Accuracy is for signals having rise and fall times ≥20ns)" :
                           CH1,CH2: ±(0.3div×V/div) (within ±4 divisions from center of screen)
                           EXT: ±(6% of setting + 40mV)
                           EXT/5: ±(6% of setting + 200mV)
Holdoff Range:          100ns-10s
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
u Trigger Type


Edge:           Trigger on the rising or falling edge
Pulse Width:   Trigger (when >,<,=,≠) on positive or negative pulses   Pulse Width Range: 20ns-10s
Video:          Trigger on an NTSC, PAL, or SECAM standard video signal   Line Range: 1-525 (NTSC), 

                        1-625 (PAL/SECAM)
Slope:          Trigger (when >,<,=,≠) on a positive or negative slope ;Set Time: 20ns–10s
Overtime:       From the rising or falling edge;Set Time: 20-10s
Alternate:      Internal trigger on edge, pulse width, video or slope
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
u Measurement


Cursors:  Manual: The difference between voltage cursors △V; the difference between time cursors

                                △T;  1/△T calculated by Hz. 
                Tracing: The voltage and time at a waveform point
Automatic:    Pk-Pk, Max, Min, Mean, Cyc RMS, Frequency, Period, Rise Time, Fall Time, Positive 

                Width, Negative Width
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
u Display


Type:        Right angle 7"TFT 16-digit color LCD
Resolution:  800*480 dots
Contrast:    16 gears, with the progress bar to show adjustment
Interface:   USB host and USB slave

 

 

 
Tel: (86) 571 8886 1158    Fax: (86) 571 8885 0923
2009 Tekway Technologies Co., Ltd, Tekway R&D Building, No. 3756, NanHuan Rd. BinJiang District, Hangzhou, 310053 (China)