The colored-display DST 4062B scope is a low bandwidth economical option with the highest price&performance ratio. Widely used for a variety of measurement practices including education, basic manufacturing, quality control, individual experiments and so on. Except the different bandwidth, Tekway Technologies add all enhanced functionalities to the DST 4062B, including extraordinary waveform update rate, minimum waveform or triggering floating, high sensitivity to small signals and powerful FFT analysis functionality.

Model: DST4062B
Bandwidth:60 MHz
Real-time Sample Rate:500 MSa/s
Equivalent Sample Rate:25GSa/s
Record Length(Sample Points) :Single-channel: Maximum 1M; Dual-channel:Maximum 512K (4K,16K,40K optional)
SEC/DIV Range:4nS/div-40S/div (in a 2, 4, 8 sequence)
Delay Time Accuracy:500ps
---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Vertical:
A/D Converter: 8-bit resolution, each channel sampled simultaneously
VOLTS/DIV Range: 2mV/div~5V/div at input BNC
Position Range: ±50V(5V/div),±40V(2V/div~500mV/div),2V(200mV/div~50mV/div)±400mV(20mV/div~2mV/div)
Bandwidth Limit: 20MHz
Rise Time at BNC: ≤ 5.8ns
DC Gain Accuracy: ±4% for Sample or Average acquisition mode, 5mV/div to 2mV/div ±3% for Sample or Average acquisition mode, 5V/div to 10mV/div
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Trigger:
"Trigger Sensitivity(Edge Trigger Type)" :DC: CH1/CH2(Typical) 1div from DC to 10MHz;1.5div from 10MHz to Full EXT(Typical) 200mV from DC to 40MHz EXT/5(Typical) 1V from DC to 40MHz AC: Attenuates signals below 10Hz HF Reject: Attenuates signals above 80kHz LF Reject: Attenuates signals below 150kHz Noise Reject: Reduces trigger sensitivity
Trigger Level Range: CH1,CH2: ±8 divisions from center of screen EXT: ±1.2V EXT/5: ±6V
"Trigger Level Accuracy,typical (Accuracy is for signals having rise and fall times ≥20ns)" :
CH1,CH2: ±(0.3div×V/div) (within ±4 divisions from center of screen) EXT: ±(6% of setting + 40mV) EXT/5: ±(6% of setting + 200mV)
Holdoff Range: 100ns-10s
-------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Trigger Type:
Edge: Trigger on the rising or falling edge
Pulse Width: Trigger (when >,<,=,≠) on positive or negative pulses Pulse Width Range: 20ns-10s
Video: Trigger on an NTSC, PAL, or SECAM standard video signal Line Range: 1-525 (NTSC), 1-625 (PAL/SECAM)
Slope: Trigger (when >,<,=,≠) on a positive or negative slope ;Set Time: 20ns–10s
Overtime: from the rising or falling edge;Set Time: 20-10s
Alternate: None
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Measurement
Cursors: Manual: The difference between voltage cursors △V; the difference between time cursors △T; 1/△T calculated by Hz.
Tracing: The voltage and time at a waveform point
Automatic: Pk-Pk, Max, Min, Mean, Cyc RMS, Frequency, Period, Rise Time, Fall Time, Positive Width, Negative Width
--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
Display
Type:: Right angle 7"TFT 16-digit color LCD
Resolution:800*480 dots
Contrast:16 gears, with the progress bar to show adjustment
Interface:USB host and USB slave
|